Notice: Function amp_is_available was called incorrectly. `amp_is_available()` (or `amp_is_request()`, formerly `is_amp_endpoint()`) was called too early and so it will not work properly. WordPress is currently doing the `amp_init` hook. Calling this function before the `wp` action means it will not have access to `WP_Query` and the queried object to determine if it is an AMP response, thus neither the `amp_skip_post()` filter nor the AMP enabled toggle will be considered. It appears the plugin with slug `schema-and-structured-data-for-wp` is responsible; please contact the author. Please see Debugging in WordPress for more information. (This message was added in version 2.0.0.) in /home/pakista/public_html/wp-includes/functions.php on line 6085

Notice: Function amp_is_available was called incorrectly. `amp_is_available()` (or `amp_is_request()`, formerly `is_amp_endpoint()`) was called too early and so it will not work properly. WordPress is currently doing the `amp_init` hook. Calling this function before the `wp` action means it will not have access to `WP_Query` and the queried object to determine if it is an AMP response, thus neither the `amp_skip_post()` filter nor the AMP enabled toggle will be considered. It appears the plugin with slug `schema-and-structured-data-for-wp` is responsible; please contact the author. Please see Debugging in WordPress for more information. (This message was added in version 2.0.0.) in /home/pakista/public_html/wp-includes/functions.php on line 6085

Notice: Function amp_is_available was called incorrectly. `amp_is_available()` (or `amp_is_request()`, formerly `is_amp_endpoint()`) was called too early and so it will not work properly. WordPress is currently doing the `init` hook. Calling this function before the `wp` action means it will not have access to `WP_Query` and the queried object to determine if it is an AMP response, thus neither the `amp_skip_post()` filter nor the AMP enabled toggle will be considered. It appears the plugin with slug `schema-and-structured-data-for-wp` is responsible; please contact the author. Please see Debugging in WordPress for more information. (This message was added in version 2.0.0.) in /home/pakista/public_html/wp-includes/functions.php on line 6085

Notice: Function amp_is_available was called incorrectly. `amp_is_available()` (or `amp_is_request()`, formerly `is_amp_endpoint()`) was called too early and so it will not work properly. WordPress is currently doing the `init` hook. Calling this function before the `wp` action means it will not have access to `WP_Query` and the queried object to determine if it is an AMP response, thus neither the `amp_skip_post()` filter nor the AMP enabled toggle will be considered. It appears the plugin with slug `schema-and-structured-data-for-wp` is responsible; please contact the author. Please see Debugging in WordPress for more information. (This message was added in version 2.0.0.) in /home/pakista/public_html/wp-includes/functions.php on line 6085
Solis Inverter 8KW

Solis Inverter 8KW

Description

Solis Inverter 8KW Solis-1P(7-8)K-5G

Reliability     Safety     Capacity

S6-EH1P8K-L-PRO

Solis Inverter 8KW series hybrid inverter with many excellent features, first, Up to 32A of MPPT current input to support 182mm/210mm solar panels; Supports 6 customized charge and discharge time set with defined charging source, more friendly for battery. And can support multiple parallel machine to form single-phase or three-phase system, the maximum power of 48kW. With UPS level switching time (< 4 ms), 190A charge-discharge current, provides higher energy throughput density. Intelligent and reliable ,which is the preferred product of residential PV energy storage and small commercial PV energy storage.   solis-10kw-ongrid-inverter7-8kW Single-phase series string inverter’s efficiency of has improved dramatically.Solis-1P(7-8)kW-5G series are suitable for the installation of single-phase input pv system of residential and adopt ultra-high switching frequency, ultra-thin single four-layer board design can greatly reduce the risk caused by the connector.

8kW Single Phase Inverter

Leading Features

  • Max. efficiency 98.1%
  • Compact and lightweight
  • Wide voltage range and low startup voltage
  • 2 MPPT design with precise MPPT algorithm
  • Integrated Export Power Manager (EPM)
  • AFCI protection, proactively reduces fire risk
  • Friendly and adaptable connection to the grid
Energy Storage Inverters

Leading Features

  • Automatic UPS switching
  •   Up to 190A max charge/discharge current
  •   6 customisable charge/discharge time settings
  •   10 second 200% surge power backup overload capability
  •   Supports 1ph and 3ph flexible connection with max 48kW in parallel
  •   Supports peak shaving control in both “self-use” and “generator” mode
  •   Generator connectivity with multiple input methods and automatic generator On/Off control
  •   Compatible with lead-acid and lithium batteries, with multiple battery protection features